The platform has an area of 125m², including 90m² of laboratories in which all the analytical equipment is distributed. It was financed with the support of:
The operation CPER "Spectrométrie de masse CEISAM" of the project CISPEO is cofunded by the European Union through the funds of the region Pays de la Loire (FEDER).
UPLC-MS² high resolution (Waters)
UPLC: Acquity H-Class
MS: ESI-Q-TOF (XEVO G2-XS QTOF)
Analysis: MS, mesure de masse exacte (HRMS), MS², UPLC-MS, UPLC-MS²
Sources/probes: ESI/APCI, ASAP
Introduction modes: liquid or solid
LC-MS low resolution (Waters)
HPLC: Alliance
MS: ESI-SQ (Acquity QDa)
Detector 1: UV-VIS with diode-array (PDA 2996)
Detector 2: Multi-fluorescence detector (FLD2475)
Analysis: LC-MS, LC-UV/VIS, LC-FLD, dosages, caractérisation de molécules, suivi de cinétique de réaction
Source: ESI
GC-MS low resolution (Agilent)
GC: 7890B
MS: IE-SQ (MSD5977B)
Analysis: GC-MS, library research
Source: EI
Introduction mode : liquid
HPLC Chirale (Agilent)
HPLC: 1200 Agilent
Detector 1: UV-VIS with diode array (Agilent)
Detector 2: Polarimètre OR 2090 (JASCO)
Injection mode : autosampler
Separation mode: chirale, normale phase
Analyses: quantitative analysis of enantiomeric excess, diastereomeric ratios measurement
Screening with 9 chiral columns:
- CHIRALPAK AD-H, AS-H, IA, IB, IC
- CHIRALCEL OD-H, OJ-H
- Lux Amylose-2
- Lux Cellulose-4
UPLC dual detection (Waters)
UPLC : Acquity H-Class
Detector 1: DEDL
Detector 2: UV-VIS with diode array
Separation mode: reversed phase, HILIC, chiral reversed phase
Analysis: characterization of molecules, quantitative analysis, monitoring of kinetic reactions, quantitative analysis of enantiomeric excesses in reversed phase
HPLC (Agilent)
HPLC : 1100 Agilent
Detector 1 : UV (Agilent)
Detector 2 : RI (Agilent)
Injection mode: manual
Separation mode: normal phase
Analysis: characterization of molecules, organic synthesis monitoring
2 GC-FID Automatic injection (Agilent)
GC: 7820
Detector: FID
Injection mode: Split/Splitless autosampler
Analysis: characterization of molecules, organic synthesis monitoring, monitoring of kinetic reactions, quantitative analysis
1 GC-TCD (Agilent)
GC: 6890
Detector: TCD
Injection mode: Split/Splitless
Analysis: quantitative analysis of hydrogen, monitoring of kinetic reactions
GC manual injection (Agilent)
GC : 6890
Detector: FID
Injection mode: Split/Splitless
Analysis: characterization of molecules, organic synthesis monitoring, monitoring of kinetic reactions, quantitative analysis